- Code: C430
- Description:Thermistor abnormality after abnormality judgment: Abnormality of the thermistor is detected after a specified period of time has passed from power-ON (including ready state).
- Remedy:1,2.3. Check the thermistors, Heater and LGC board Check the above components following the procedures 1, 2 and 3 for [C410]. 4. Clear the status counter Change the current status counter value (08-400) “4” to “0” for [C430] and “5”, “7” or “9” to “0” for [C440], taking the same procedure as that for [C410]. * The status counter value is as follows in the following cases. Change them to “0” respectively. • The error occurred during warming-up: “4” or “5” • The error occurred after the equipment has become ready: “7” • The temperature detected by the center thermistor is 230°C or higher: “9” • The temperature detected by the side thermistor is 230°C or higher: “9” • The temperature detected by the edge thermistor is 230°C or higher: “9” only during printing.