Toshiba e-Studio 232 Code: E280
- Code: E280
- Description:ADU transport jam (paper not reaching the registration sensor): The paper which has passed through ADU and the 1st transport sensor does not reach the registration sensor during duplex printing.
- Remedy:Open the transfer cover. Is there paper in front of the registration sensor? YES Remove the paper. NO Is the registration sensor working? (Perform the input check in the test mode: 03-[FAX]ON/[2]/[A] NO 1) Check if the connector of the registration sensor is disconnected. 2) Check if the connector CN305 on the LGC board is disconnected. 3) Check if the connector pins are disconnected and the harnesses are open circuited. 4) Check if the conductor pattern on the LGC board is short circuited or open circuited. 5) Replace the registration sensor. 6) Replace the LGC board. YES Is the registration clutch working? (Perform the output check in the test mode: 03-108/158) NO 1) Check if the connector of the registration clutch is disconnected. 2) Check if the connector CN305 on the LGC board is disconnected. 3) Check if the connector pins are disconnected and the harnesses are open circuited. 4) Check if the conductor pattern on the LGC board is short circuited or open circuited. 5) Replace the registration roller clutch. 6) Replace the LGC board. YES Check the registration roller. Replace it if it is worn out.