- Code: E480
- Description:Bridge unit open jam: The bridge unit has opened during printing.
- Remedy:Is the bridge unit open? YES Remove the paper if there is any, then close the unit. NO Is the bridge unit opening/closing switch working? (Perform the input check in the test mode: 03-[FAX]ON/[3]/[F]) NO 1) Check if the connector of the bridge unit opening/closing switch is disconnected. 2) Check if the connector CN306 on the LGC board is disconnected. 3) Check if the connector pins are disconnected and the harnesses are open circuited. 4) Check if the conductor pattern on the LGC board is short circuited or open circuited. 5) Replace the bridge unit opening/closing switch. 6) Replace the LGC board. YES Replace the LGC board