Toshiba e-Studio 232 Code: E490
- Code: E490
- Description:Job separator cover open jam: The job separator cover has opened during printing.
- Remedy:Is the JSP cover open? YES Remove the paper if there is any, then close the cover. NO Is the JSP cover switch working? (Perform the input check in the test mode: 03-[FAX]ON/[3]/[F]) NO 1) Check if the connector of the JSP cover switch is disconnected. 2) Check if either of the connectors CN260 or CN261 on the JSP board is disconnected. 3) Check if the connector CN306 on the LGC board is disconnected. 4) Check if the connector pins are disconnected and the harnesses are open circuited. 5) Check if the conductor patterns on the JSP board and LGC board are short circuited or open circuited. 6) Replace the JSP cover switch. 7) Replace the JSP board. 8) Replace the LGC board. YES 1) Replace the JSP board. 2) Replace the LGC board