Toshiba e-Studio 232 Code:E400

 

  • Code: E400
  • Description:Transfer cover open jam: The transfer cover has opened during printing.
  • Remedy:Is the transfer cover open? YES Remove paper if there is any, then close the cover. NO Is the transfer cover opening/closing switch working? (Perform the input check in the test mode: 03-[FAX]ON/[2]/[G]) NO 1) Check if the connector of the transfer cover opening/closing switch is disconnected. 2) Check if the connector CN305 on the LGC board is disconnected. 3) Check if the connector pins are disconnected and the harnesses are open circuited. 4) Check if the conductor pattern on the LGC board is short circuited or open circuited. 5) Replace the front cover opening/closing switch. 6) Replace the LGC board. YES Replace the LGC board. Is the voltage of 24V being supplied from the power supply unit? (Perform the input check in the test mode: 03-[FAX] ON/[1]/[C]) NO 1) Check if the connector for 24 V power supply is disconnected. 2) Check if the connector CN305 on the LGC board is disconnected. 3) Check if the connector pins are disconnected and the harnesses are open circuited. 4) Check if the conductor pattern on the LGC board is short circuited or open circuited. 5) Replace the LGC board. YES Replace the LGC board.