Toshiba e-Studio 232 Code:E420

 

  • Code: E420
  • Description:PFP side cover open jam: The PFP side cover has opened during printing.
  • Remedy:Is the PFP side cover open? YES Remove the paper if there is any, then close the cover. NO Is the PFP side cover opening/closing switch working? (Perform the input check in the test mode: 03-[FAX]OFF/[2]/[F]) NO 1) Check if the connector of the PFP side cover opening/closing switch is disconnected. 2) Check if either of the connectors CN241 or CN243 on the PFP board is disconnected. 3) Check if the connector CN310 on the LGC board is disconnected. 4) Check if the connector pins are disconnected and the harnesses are open circuited. 5) Check if the conductor patterns on the PFP board and LGC board are short circuited or open circuited. 6) Replace the PFP side cover opening/closing switch. 7) Replace the PFP board. 8) Replace the LGC board. YES 1) Replace the PFP board. 2) Replace the LGC board.